Model No.︰Q3HB220M
Brand Name︰JB
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
R-1
|
0
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
A
|
B
|
C
|
D
|
E
|
F
|
Im (A)
|
0.6
|
1.1
|
1.5
|
2.0
|
2.5
|
2.9
|
3.2
|
3.6
|
4
|
4.5
|
5
|
5.5
|
5.8
|
6.3
|
6.6
|
7.0
|
SK1
|
F
|
E
|
D
|
C
|
B
|
A
|
9
|
8
|
7
|
6
|
5
|
4
|
3
|
2
|
1
|
0
|
s/r
|
400
|
500
|
600
|
800
|
1000
|
1200
|
2000
|
3000
|
4000
|
5000
|
6000
|
10000
|
12000
|
20000
|
30000
|
60000
|
DP3
|
OFF, double pulse: PU is positive pulse signal, DR is negative pulse signal
|
ON, single pulse: PU is pulse signal, DR is direction signal
|
|
DP4
|
Self detect switch (OFF: accept pulse input, ON: send out 7.5KHz pulse. The subdivision should be between 2000-10000 s/r)
|
Mark
|
Function
|
Specification
|
MF+
|
Positive of opto-isolated
|
Connected to +5V power supply. Driven voltage range from +5V to +24V. Current-limiting resistance is needed when over 5V.
|
MF-
|
Motor free signal
|
The motor current will be cut off and the drive stops working when it effects.
|
SM+
|
Positive of opto-isolated
|
Connected to +5V power supply. Driven voltage range from +5V to +24V. Current-limiting resistance is needed when over 5V.
|
SM-
|
Subdivision choosing signal
|
Choose subdivision by SK1 when low voltage and SK2 when high voltage. Input resistance is 220Ω.
|
DR+
|
Positive of opto-isolated
|
Connected to +5V power supply. Driven voltage range from +5V to +24V. Current-limiting resistance is needed when over 5V.
|
DR-
|
DP3=ON, DR is direction signal
|
Change the motor’s direction of rotation. Input resistance is 220Ω. Low voltage 0-0.5V, high voltage 4-5V, pulse width>2.5μS
|
DP1=OFF, DR is negative pulse signal
|
||
PU+
|
Positive of opto-isolated
|
Connected to +5V power supply. Driven voltage range from +5V to +24V. Current-limiting resistance is needed when over 5V.
|
PU-
|
DP3=ON, PU is pulse signal
|
With the falling edge of the signal PU, the motor executes an angular step. The input resistance is 220Ω. Low voltage 0-0.5V, high voltage 4-5V, pulse width>2.5μS.
|
DP3=OFF, PU is positive pulse signal
|
||
TM+
|
Positive of opto-isolated origin output signal
|
When the motor current is on, the motor is at the origin position. Opto-isolated output (high voltage). Connect TM+ to current-limiting resistance, TM- to ground. The maximum driven current is 50mA, the highest driven voltage is 50V.
|
TM-
|
Negative of opto-isolated origin output signal
|
|
RDY+
|
Positive of opto-isolated ready signal
|
It is active (low voltage) when the drive is ready for receiving controller’s signal.
|
RDY-
|
Negative of opto-isolated ready siangl
|
|
~AC
|
Power supply
|
AC110V~220V
|
U
|
Connection
|
|
V
|
||
W
|
Payment Terms︰ Paypal,bank transfer,TT/LC/DP/DA